Info: | Load limit |
Data type: | REAL |
Description:
Runtime error if the load of the motor temperature model LOAD_MOTOR_MODEL exceeds the limit (see INFO).
Reaction:
See error number 9001
Cause/Remedy:
During the movement stop (see error number 9070), the load of the motor temperature model increases.
If the movement would be stopped in already in deeper loads, the limit load (see INFO) would not be exceeded.