Info: | |
Data type: |
Description:
Response error while writing the SEP_ULONG_WR and SEP_FLOAT_WR parameters or while reading the SEP_ULONG_RD and SEP_FLOAT_RD parameters.
Reaction:
None.
Cause/Remedy:
The access counter is incremented after each read and write procedure for the above parameters.
Caution: Internal parameter for writing the EEPROM. False usage can cause damage to the ACOPOS servo drive.