Info: | Distance |
Data type: | DINT |
Description:
Runtime error while referencing with distance-coded reference marks. The distance between two reference marks is 0 or is larger than the general distance for reference marks ENCODX_REF_DCM_DISTANCE.
Reaction:
See error number 5035.
Cause/Remedy:
The configured general distance does not match the general distance for reference marks of the encoder (check encoder data sheet).
Reference signal encoder connection is interrupted or defective (see wiring guidelines error number 7030).
Encoder does not support reference marks (check encoder data sheet).
Encoder reference signal does not meet the specifications of the plug-in card (check encoder data sheet).
Encoder measure is no longer clean.
Encoder defective.
AC120, AC123 or AC130 plug-in card defect.