5109: Master compensation trigger FIFO empty

Info:
Data type:

Description:
Runtime error when cam automat is active (CMD_CAM_START) if the compensation trigger FIFO for the master axis is empty.

Reaction:
See error number 4008.

Cause/Remedy:
No trigger signal when FIFO size is 1 (CAM_MA_S_COMP_TRIG small) in connection with a large trigger window (CAM_MA_COMP_TRIG_WINDOW).
The information 'Product not available' is entered after the window position has been exceeded.