32130: This external set position mode is only allowed with one CAN interface

Info: Count of used CAN interfaces
Data type: UINT

Description:
This external set position mode is not allowed for the operation of ACOPOS servo drives via the CAN network if multiple CAN interfaces are defined in the NC configuration.

Reaction:
Initialization of the NC software is aborted. No NC objects can be operated:

Cause/Remedy:
Reduce the number of CAN interfaces in the NC configuration to one or deactivate the external set position mode.